Seismic design system for buried pipelines
Design standards for land improvement projects, in accordance with the Japan Sewage Works Association and the Japan Water Works Association. Consideration of seismic design for buried pipes in the longitudinal direction and the expansion amount under normal loads.
This is a system for seismic design of buried pipelines in the longitudinal direction, compliant with the "Land Improvement Design Standards," the "Japan Sewage Works Association," and the "Japan Water Works Association." It also examines earthquake behavior for Level 1 and Level 2 seismic motions, assesses liquefaction, and analyzes expansion and contraction under constant loads. The buried pipelines subject to examination include the manhole section, pipe joint section, and the connection between pipe sections. Calculation reports can be printed with data input, detailed calculations, and a summary table with a table of contents. Additionally, conversion to Word via RTF is also possible.
- Company:SIPシステム 大阪事務所
- Price:100,000 yen-500,000 yen